PROPERTY ENERGY EFFICIENCY CERTIFICATE DETAILS
Calder Street, COLNE, BB8 0DG

Introduction

Energy Performance Certificates (EPCs) are designed to tell you how efficient a building is and provides a rating between A (very efficient) and G which is inefficient. It helps to identify how costly it will be to light and heat a property and what the carbon dioxide emissions are likely to be.

An EPC needs to be provided as part of the process of selling or renting a house and should be availale as soon as the property is marketed. An EPC may only be produced by an approved domestic energy assessor and each certificate is valid for 10 years.

Additionally, an EPC will highlight potential efficiency improvements that could be made to the property, an estimated cost for implementation and the likely savings that can be made as a result. These costs and savings are for a typical household in that property and not specific to you or your family.

Certificates issued for Calder Street, BB8 0DG are shown below and the data are updated monthly for England and Wales and quarterly for properties in Scotland.

Data are provided by the Department for Levelling Up, Housing and Communities.

Energy Performance Certificates Generated for Calder Street, COLNE, BB8 0DG
Period Covered: 2008 - 31 October 2024

Address
Inspection Date
Current
Potential
Property Type
Built Form
Constructed
Address
13 CALDER STREET, COLNE
Date
23 Sep 2020
Current
Potential
63
79
Property Type
House
Built Form
Mid-Terrace
Constructed
before 1900
+
Certificate History
23 Sep 2020
63
79
Total Floor Area
127 sq m
Current CO2 Emissions Level
6.4
Potential CO2 Emissions Level
4.0
CO2 per sq m per Year
51
Mains Gas Available
Yes
Habitable Rooms
5
Number of Extensions
1
Address
15 Calder Street
Date
10 Apr 2022
Current
Potential
26
76
Property Type
House
Built Form
Mid-Terrace
Constructed
1900-1929
+
Certificate History
10 Apr 2022
26
76
Total Floor Area
123 sq m
Current CO2 Emissions Level
14.0
Potential CO2 Emissions Level
4.4
CO2 per sq m per Year
116
Mains Gas Available
Yes
Habitable Rooms
6
Number of Extensions
0
Address
17 Calder Street
Date
22 Aug 2016
Current
Potential
53
79
Property Type
House
Built Form
Mid-Terrace
Constructed
before 1900
+
Certificate History
22 Aug 2016
53
79
Total Floor Area
123 sq m
Current CO2 Emissions Level
8.2
Potential CO2 Emissions Level
3.9
CO2 per sq m per Year
66
Mains Gas Available
Yes
Habitable Rooms
5
Number of Extensions
0
Address
19 Calder Street
Date
18 Nov 2019
Current
Potential
56
81
Property Type
House
Built Form
Mid-Terrace
Constructed
1900-1929
+
Certificate History
18 Nov 2019
56
81
24 Mar 2009
44
54
Total Floor Area
138 sq m
Current CO2 Emissions Level
8.4
Potential CO2 Emissions Level
3.8
CO2 per sq m per Year
61
Mains Gas Available
Yes
Habitable Rooms
5
Number of Extensions
1
Address
21 Calder Street
Date
11 Mar 2024
Current
Potential
53
80
Property Type
House
Built Form
Mid-Terrace
Constructed
before 1900
+
Certificate History
11 Mar 2024
53
80
3 Aug 2020
51
79
12 Feb 2015
19
82
Total Floor Area
111 sq m
Current CO2 Emissions Level
6.8
Potential CO2 Emissions Level
2.9
CO2 per sq m per Year
62
Mains Gas Available
Yes
Habitable Rooms
4
Number of Extensions
1
Address
25 Calder Street
Date
29 Apr 2009
Current
Potential
66
73
Property Type
House
Built Form
Mid-Terrace
Constructed
before 1900
+
Certificate History
29 Apr 2009
66
73
Total Floor Area
83 sq m
Current CO2 Emissions Level
4.4
Potential CO2 Emissions Level
3.5
CO2 per sq m per Year
42
Mains Gas Available
Yes
Habitable Rooms
5
Number of Extensions
1
Address
27 Calder Street
Date
3 Jun 2024
Current
Potential
37
81
Property Type
House
Built Form
End-Terrace
Constructed
before 1900
+
Certificate History
3 Jun 2024
37
81
Total Floor Area
116 sq m
Current CO2 Emissions Level
11.0
Potential CO2 Emissions Level
3.2
CO2 per sq m per Year
93
Mains Gas Available
Yes
Habitable Rooms
5
Number of Extensions
2
Address
3 Calder Street
Date
3 Sep 2018
Current
Potential
38
81
Property Type
House
Built Form
End-Terrace
Constructed
1900-1929
+
Certificate History
3 Sep 2018
38
81
Total Floor Area
128 sq m
Current CO2 Emissions Level
12.0
Potential CO2 Emissions Level
3.6
CO2 per sq m per Year
90
Mains Gas Available
Yes
Habitable Rooms
6
Number of Extensions
1
Address
4 Calder Street
Date
6 Jun 2012
Current
Potential
33
85
Property Type
House
Built Form
Mid-Terrace
Constructed
1900-1929
+
Certificate History
6 Jun 2012
33
85
Total Floor Area
95 sq m
Current CO2 Emissions Level
7.9
Potential CO2 Emissions Level
1.4
CO2 per sq m per Year
84
Mains Gas Available
Yes
Habitable Rooms
4
Number of Extensions
0
Address
5 Calder Street
Date
18 Feb 2014
Current
Potential
57
71
Property Type
House
Built Form
Mid-Terrace
Constructed
before 1900
+
Certificate History
18 Feb 2014
57
71
9 Aug 2012
27
71
Total Floor Area
129 sq m
Current CO2 Emissions Level
6.3
Potential CO2 Emissions Level
4.3
CO2 per sq m per Year
49
Mains Gas Available
Yes
Habitable Rooms
5
Number of Extensions
1
Address
7 Calder Street
Date
18 Mar 2016
Current
Potential
55
80
Property Type
House
Built Form
Mid-Terrace
Constructed
before 1900
+
Certificate History
18 Mar 2016
55
80
18 Mar 2016
50
80
Total Floor Area
168 sq m
Current CO2 Emissions Level
10.0
Potential CO2 Emissions Level
4.8
CO2 per sq m per Year
61
Mains Gas Available
Yes
Habitable Rooms
5
Number of Extensions
0
Address
8 Calder Street
Date
20 Mar 2020
Current
Potential
67
83
Property Type
House
Built Form
End-Terrace
Constructed
1900-1929
+
Certificate History
20 Mar 2020
67
83
Total Floor Area
137 sq m
Current CO2 Emissions Level
5.9
Potential CO2 Emissions Level
3.4
CO2 per sq m per Year
43
Mains Gas Available
Yes
Habitable Rooms
5
Number of Extensions
1
Address
9 Calder Street
Date
5 Aug 2024
Current
Potential
56
83
Property Type
House
Built Form
Mid-Terrace
Constructed
before 1900
+
Certificate History
5 Aug 2024
56
83
14 Mar 2014
31
70
Total Floor Area
138 sq m
Current CO2 Emissions Level
8.5
Potential CO2 Emissions Level
3.4
CO2 per sq m per Year
61
Mains Gas Available
Yes
Habitable Rooms
5
Number of Extensions
0
Bands

A
92 - 100
B
81 - 91
C
69 - 80
D
55 -68
E
39 -54
F
54 -38
G
0 - 20

Energy Performance Certificate Notes

There are a number of reasons that certificates are excluded from the dataset;

  • The holder of the energy certificate has 'opted-out' of disclosure
  • The certificate is excluded on the grounds of national security
  • Certificates that are marked as 'cancelled' or 'not for issue'

Certificates are grouped together by the property reference identifier rather than the postal address with a view to showing the history of changes made to properties over time. Sometimes, one property may exist as multiple entries in the table instead and this is as a result of inconsistent building references being used on each prepared certificate.

Contains public sector information licensed under the Open Government Licence v3.0.
Contains Royal Mail data © Royal Mail copyright and Database right 2024.